Enabling logging
Device logging
1 Open a command prompt.
2 Run the following command: rsh <IPAddress> mmesg_auto 125
Where IPAddress is the IP address of the device that you are trouble shooting.
Embedded AccuRoute for Intelligent Devices (Omtool ISAPI web server extension) logging
1 Open the Registry Editor.
2 Browse to hkey_local_machine\software\Wow6432Node\Omtool\WEBAPI.
3 Change the DWORD setting for DebugEnabled from 0 to 1.
4 Create a directory under C:\ call it Debug, specify a folder under Debug directory with the same
name.
5 Stop and start World Wide Web Publishing Service.
This is how the Registry Editor should look: