Setting Explanation
Polling interval time for other
information
Specify the frequency at which Remote Communication Gate S polls
devices for other status information. Enter a number and select [min.],
[hour(s)], or [day(s)] from the menu.
The time you specify here is the time that will elapse between polling.
• Default: 6 hours
•
Valid values: 1 min. - 7 days
Interval between collection of
internal and administrator
counters
Specify the frequency at which Remote Communication Gate S polls
devices
for the collection of internal and administrator counters. Enter a
number and select [min.], [hour(s)], or [day(s)] from the menu.
The time you specify here is the time that will elapse between polling.
• Default: 1 day
•
Valid values: 1 min: - 7 days
Polling timeout: Enter the number of seconds to wait for a response from a device.
If
the machine receives no response when polling a device, it continues
attempting polling for a specified period. Polling is cancelled after this
period.
• Default: 3 sec.
•
Valid values: 0.5 - 60 sec.
• Periodic
polling cannot retrieve the following information from devices that are in energy saving mode:
• Log transfer settings
• SSL settings
• Transmission counter figures (Send/TX Total B&W Counter, Send/TX Total Color Counter, Fax
Transmission Counter, Scanner Send B&W Counter, and Scanner Send Color Counter)
• To retrieve the latest information from a device, first select the device on the Printer Management
screen. Then, on the [Printer] menu, select [Refresh Selected Device]; or, on the [Printer] menu on the
Printer Properties screen, select [Refresh Device].